Product introduction
DC reactor core columns fasteners adopt non-magnetic materials, ensure that the reactor has the advantages of low temperature rise.
Data download
One, product introduction
      DC reactor, also known as the flat wave reactor, mainly used for DC converter,applications have more general inverter. DC current has an AC component isthrough the DC reactor, the main purpose is to the AC component in the DCcurrent is limited to a specified value, keep the rectified current continuously,reduce current ripple, improve the input power factor and reduce and preventfrom impulse current caused by rectifier bridge damage and capacitoroverheating, harmonic and inhibition causes a flow device.
Two, performance specification

1. the DC reactor for single-phase iron core dry type structure;

2. core with high-quality low loss cold-rolled silicon steel sheet, the stem by multiple air gap between uniform pieces, air gap epoxy glass cloth laminated board spacing, and coated with a special adhesive, to ensure that the air gap reactance in operation process does not change without noise;

3. Coil with class F or class H enamelled copper flat wire winding, closely spaced and uniformly, appearance of the insulation layer, small volume coil adopts alayer type structure, large capacity coil adopts a cake type structure, has goodventilation and heat dissipation effect;

4. The coil and the iron core DC reactor are assembled into a whole after pre drying-- vacuum impregnation -- heat drying curing this process, using H level varnish,make the reactor coil and core tightly together, not only greatly reduce operating noise, and have high heat-resistant level, ensure reactor can no noise, safeoperation at high temperature;

5. DC reactor core columns fasteners adopt non-magnetic materials, ensure that the reactor has the advantages of low temperature rise;

6. exposed without are adopted for corrosion resistance, leads to terminal adopts tin brass or copper.
Three, the technical parameters

Rated voltage: <3000VDC, 50/60 (Hz)

Rated current: 5 ~ 1600 (A)

Operating and storage: -25 ~ +40 (c)

Insulation grade: F/H

Shell protection grade: IPOO/IP23

Humidity: 0 ~ 98 (%) do not

Height: <1000M

 
 